Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Physiother Res Int ; 27(4): e1961, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: covidwho-1894624

RESUMEN

BACKGROUND AND PURPOSE: The therapeutic benefits of prone positioning have been described over the last 50 years culminating in a systematic review supporting this management strategy for patients with severe hypoxaemic respiratory failure. Early work detailing treatment approaches for COVID-19 have advocated the use of prone positioning. Limited data exists regarding physiotherapy intervention in patients with COVID-19 owing to the recent emergence of this novel disease. Despite the acknowledged beneficial effects of physiotherapy on secretion clearance and lung recruitment in the general critical care population, there is a lack of evidence pertaining to physiotherapeutic intervention for acutely unwell intubated adults in prone lying. METHODS: This case study report follows the CARE case report guidelines. One patient with COVID-19 pneumonitis who underwent physiotherapy intervention in prone lying is discussed. Informed consent was gained from next of kin for data to be published. RESULTS: Treatment techniques including mechanical insufflation-exsufflation in prone were feasible and well tolerated by this patient with only transient adverse effects noted. Treatment techniques assisted with secretion clearance. DISCUSSION: Further work on safety, feasibility, and efficacy of physiotherapy intervention in patients with and without COVID-19 in prone will contribute to the evidence base on this subject.


Asunto(s)
COVID-19 , Insuflación , Insuficiencia Respiratoria , Adulto , Cuidados Críticos/métodos , Humanos , Insuflación/efectos adversos , Insuflación/métodos , Respiración Artificial , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia
3.
J Laryngol Otol ; 135(1): 86-87, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: covidwho-1065742

RESUMEN

BACKGROUND: Since the start of the coronavirus disease 2019 pandemic, transnasal humidified rapid-insufflation ventilatory exchange ('THRIVE') has been classified as a high-risk aerosol-generating procedure and is strongly discouraged, despite a lack of conclusive evidence on its safety. METHODS: This study aimed to investigate the safety of transnasal humidified rapid-insufflation ventilatory exchange usage and its impact on staff members. A prospective study was conducted on all transnasal humidified rapid-insufflation ventilatory exchange cases performed in our unit between March and July 2020. RESULTS: During the study period, 18 patients with a variety of airway pathologies were successfully managed with transnasal humidified rapid-insufflation ventilatory exchange. For each case, 7-10 staff members were present. Appropriate personal protective equipment protocols were strictly implemented and adhered to. None of the staff involved reported symptoms or tested positive for coronavirus disease 2019, up to at least a month following their exposure to transnasal humidified rapid-insufflation ventilatory exchange. CONCLUSION: With strictly correct personal protective equipment use, transnasal humidified rapid-insufflation ventilatory exchange can be safely employed for carefully selected patients in the current pandemic, without jeopardising the health and safety of the ENT and anaesthetic workforce.


Asunto(s)
COVID-19/terapia , Insuflación , Respiración Artificial , Humanos , Humidificadores , Insuflación/métodos , Nariz , Estudios Prospectivos , Respiración Artificial/métodos , Factores de Tiempo
5.
ANZ J Surg ; 90(10): 2080-2081, 2020 10.
Artículo en Inglés | MEDLINE | ID: covidwho-860432

RESUMEN

Aerosolization during laparoscopy poses a theoretical risk of infection to healthcare providers by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A simple, low-cost method of controlled abdominal desufflation during laparoscopy is described.


Asunto(s)
COVID-19/prevención & control , COVID-19/transmisión , Transmisión de Enfermedad Infecciosa de Paciente a Profesional , Insuflación/métodos , Laparoscopía/métodos , Diseño de Equipo , Humanos , Insuflación/instrumentación
6.
Surg Endosc ; 35(1): 493-501, 2021 01.
Artículo en Inglés | MEDLINE | ID: covidwho-792429

RESUMEN

BACKGROUND: Viral particles have been shown to aerosolize into insufflated gas during laparoscopic surgery. In the operating room, this potentially exposes personnel to aerosolized viruses as well as carcinogens. In light of circumstances surrounding COVID-19 and a concern for the safety of healthcare professionals, our study seeks to quantify the volumes of gas leaked from dynamic interactions between laparoscopic instruments and the trocar port to better understand potential exposure to surgically aerosolized particles. METHODS: A custom setup was constructed to simulate an insufflated laparoscopic surgical cavity. Two surgical instrument use scenarios were examined to observe and quantify opportunities for insufflation gas leakage. Both scenarios considered multiple configurations of instrument and trocar port sizes/dimensions: (1) the full insertion and full removal of a laparoscopic instrument from the port and (2) the movement of the scope within the port, recognized as "dynamic interaction", which occurs nearly 100% of the time over the course of any procedure. RESULTS: For a 5 mm instrument in a 5 mm trocar, the average volume of gas leaked during dynamic interaction and full insertion/removal scenarios were 43.67 and 25.97 mL of gas, respectively. Volume of gas leaked for a 5 mm instrument in a 12 mm port averaged 41.32 mL and 29.47 for dynamic interaction vs. instrument insertion and removal. Similar patterns were shown with a 10 mm instrument in 12 mm port, with 55.68 mL for the dynamic interaction and 58.59 for the instrument insertion/removal. CONCLUSIONS: Dynamic interactions and insertion/removal events between laparoscopic instruments and ports appear to contribute to consistent leakage of insufflated gas into the OR. Any measures possible taken to reduce OR gas leakage should be considered in light of the current COVID-19 pandemic. Minimizing laparoscope and instrument removal and replacement would be one strategy to mitigate gas leakage during laparoscopic surgery.


Asunto(s)
COVID-19/prevención & control , Control de Infecciones/métodos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Laparoscopía/métodos , Enfermedades Profesionales/prevención & control , Exposición Profesional/prevención & control , Personal de Hospital , Aerosoles , COVID-19/transmisión , Humanos , Insuflación/instrumentación , Insuflación/métodos , Laparoscopía/instrumentación
7.
Neurology ; 95(15): 693-694, 2020 10 13.
Artículo en Inglés | MEDLINE | ID: covidwho-690840

RESUMEN

Coronavirus disease 2019 (COVID-19) may pose unique challenges to clinicians attempting to diagnose brain death in patients infected with the SARS-CoV-2. Among these challenges is the risk of aerosol generation during the traditional apnea testing using the insufflation technique in addition to the risk of complications due to SARS-CoV-2-related lung disease. In this article, we discuss these challenges and provide further guidance to minimize such risks to ensure safety of healthcare professionals and other patients. We also emphasize the importance of maintaining the standards of brain death determination in this critical time.


Asunto(s)
Muerte Encefálica/diagnóstico , Infecciones por Coronavirus/prevención & control , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Examen Neurológico/métodos , Pandemias/prevención & control , Neumonía Viral/prevención & control , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/transmisión , Humanos , Insuflación/métodos , Neumonía Viral/transmisión , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA